Chapter 1 Setting Up the Server Hardware 7
4. Simultaneously pull and hold the slide-rail release buttons on each mounting
bracket while you push the server into the rack. See
FIGURE 1-4. Continue pushing
until the slide-rail locks on the front of the mounting brackets engage the slide-
rail assemblies.
Caution Verify that the server is securely mounted in the rack and that the slide-
rails locks are engaged with the mounting brackets before continuing.
Installing the Cable Management Assembly
Use this procedure to install an optional cable management assembly (CMA).
1. Unpack the CMA parts.
2. Take the CMA to the rear of the equipment rack and ensure that you have
adequate room to work around the rear of the server.
Note References to “left” or “right” in this procedure assume that you are facing
the rear of the equipment rack.
3. Locate the CMA rail extension and insert it into the left slide-rail until the
extension locks into place with an audible click. See
FIGURE 1-5.
FIGURE 1-5 Inserting the CMA Rail Extension Into the Rear of the Left Slide-Rail
CMA rail
extension
Left slide-rail