Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Sun Fire
X4100 and Sun Fire X4200
Servers Installation Guide
For:
Sun Fire X4100
Sun Fire X4200
Sun Fire X4100 M2
Sun Fire X4200 M2
Part No. 819-1155-15
October 2006, Revision A
Seitenansicht 0
1 2 3 4 5 6 ... 49 50

Inhaltsverzeichnis

Seite 1 - Servers Installation Guide

Sun Microsystems, Inc.www.sun.comSubmit comments about this document at: http://www.sun.com/hwdocs/feedbackSun Fire™X4100 and Sun Fire X4200Servers In

Seite 2

2 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 20065. Configure the preinstalled Solaris™ operating system or install a supportedope

Seite 3 - Contents

Chapter 1 Setting Up the Server Hardware 3Disassembling the Slide-Rails Before InstallationUse this procedure to remove the mounting brackets from the

Seite 4

4 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Installing the Mounting Brackets Onto the ServerUse this procedure to install the

Seite 5 - Related Documentation

Chapter 1 Setting Up the Server Hardware 5Attaching the Slide-Rail Assemblies to the RackUse this procedure to install the slide-rail assemblies to th

Seite 6 - Third-Party Web Sites

6 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Installing the Server Into the Slide-RailAssembliesUse this procedure to install

Seite 7 - Sun Welcomes Your Comments

Chapter 1 Setting Up the Server Hardware 74. Simultaneously pull and hold the slide-rail release buttons on each mountingbracket while you push the se

Seite 8

8 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 20064. Verify that the CMA rail extension engages the slide-rail, as shown in FIGURE

Seite 9 - Installation Overview

Chapter 1 Setting Up the Server Hardware 9FIGURE 1-7 Inserting the CMA Mounting Bracket Into the Rear of the Right Slide-Rail6. Insert the right CMA s

Seite 10 - Optional Slide-Rails

10 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 20067. Insert the remaining CMA arm connector into the plastic cutout on the CMA rai

Seite 11 - Mounting bracket

Chapter 1 Setting Up the Server Hardware 11FIGURE 1-10 Installing CMA Cable HangersAttaching and Routing CablesUse this procedure to attach cables to

Seite 12 - Mounting-bracket clip

Copyright 2005 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems, Inc. has intel

Seite 13 - FIGURE 1-3

12 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Verifying Operation of the Slide-Rails and CMAUse this procedure to ensure that

Seite 14 - Assemblies

Chapter 1 Setting Up the Server Hardware 13CablingAttach cables to the back panel connectors of your server as required. See FIGURE 1-11or FIGURE 1-12

Seite 15 - Left slide-rail

14 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 20064. Connect Ethernet cables to the “NET” connectors as required for your GigabitE

Seite 16 - CMA rail extension

Chapter 1 Setting Up the Server Hardware 15Powering On and Powering Off theServerYou have to apply only standby power to the server at this point so t

Seite 17 - FIGURE 1-8

16 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Powering On Main Power Mode● To power on main power for all server components:a.

Seite 18 - FIGURE 1-10

Chapter 1 Setting Up the Server Hardware 17 Emergency shutdown: Press and hold the Power button for four seconds to forcemain power off and enter sta

Seite 19 - Attaching and Routing Cables

18 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006

Seite 20

19CHAPTER2Setting Up the Server SoftwareThis chapter describes the tasks for initial setup of the server’s service processor andIntegrated Lights Out

Seite 21 - FIGURE 1-12

20 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006ILOM consists of four components, three of which are on your host server and one

Seite 22

Chapter 2 Setting Up the Server Software 21Connecting to the ILOM ServiceProcessorThere are two methods for connecting to the ILOM SP to perform initi

Seite 23 - Processor Configuration

iiiContentsPreface v1. Setting Up the Server Hardware 1Installation Overview 1Installing the Server Into a Rack With Optional Slide-Rails 2Disassembli

Seite 24 - Shutting Down Main Power Mode

22 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 20064. Press Enter on the terminal device to establish a connection between that ter

Seite 25

Chapter 2 Setting Up the Server Software 23Connecting to ILOM Using an EthernetConnectionTo access the full range of ILOM functionality such as the gr

Seite 26

24 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006a. Identify the MAC address of the ILOM SP from one of the following locationsan

Seite 27

Chapter 2 Setting Up the Server Software 25FIGURE 2-2 Opening a Session With an SSH Command-Line Interface To establish a connection to the ILOM SP w

Seite 28

26 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Configuring ILOM Using Static Ethernet SettingsAs an alternative to having your

Seite 29 - Processor

Chapter 2 Setting Up the Server Software 27FIGURE 2-4 Integrated Lights Out Manager Network Settings PageConfiguring Static IP Addresses Using the CLI

Seite 30

28 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Configuring Static IP Addresses Using the BIOS Setup Utility1. Enter the BIOS Se

Seite 31 - Connection

Chapter 2 Setting Up the Server Software 29Setting Up Platform Operating Systemand Driver SoftwareAfter configuring the ILOM SP with network settings,

Seite 32 - FIGURE 2-2

30 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006

Seite 33

31CHAPTER3Configuring the Pre-installedSolaris 10 Operating SystemThis chapter explains the steps for configuring the Solaris™10 Operating System(OS)

Seite 34 - FIGURE 2-4

iv Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Connecting to the ILOM Service Processor 21Connecting to ILOM Using a Serial Con

Seite 35

32 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006TABLE 1 Worksheet for InstallationInformation for Installation Description or Ex

Seite 36

Chapter 3 Configuring the Pre-installed Solaris 10 Operating System 33Name service:if the systemuses a nameservice, providethe followinginformation.Na

Seite 37

34 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Default route Do you want to specify a default route IP addressor let the Solari

Seite 38

Chapter 3 Configuring the Pre-installed Solaris 10 Operating System 35Configuring the Pre-Installed Solaris 10Operating SystemNote – Before you perfor

Seite 39 - Solaris 10 Operating System

36 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006▼ To Connect to the Server Using the ServiceProcessor’s IP AddressNote – This pr

Seite 40 - Worksheet for Installation

Chapter 3 Configuring the Pre-installed Solaris 10 Operating System 37The screens that are displayed will vary, depending on the method that you chose

Seite 41 - Defaults are noted

38 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006▼ To Connect to the Server Using a Serial CaptureProgram1. Use a cable to connec

Seite 42 - from GM

Chapter 3 Configuring the Pre-installed Solaris 10 Operating System 39Solaris 10 User DocumentationYou can access the various collections of the Solar

Seite 43 - Operating System

40 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006

Seite 44 - Processor’s IP Address

41IndexBback panel cable connectors 13back panel illustration 13Ccable management assembly 7cables 13client-side secure shell 20CMA assembly 7connecto

Seite 45

vPrefaceThis Sun Fire X4100 and Sun Fire X4200 Installation Guide contains procedures forinstalling the server in a rack, cabling, and powering on the

Seite 46 - $tip -9600 /dev/ttya

42 Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006configuring with Ethernet 23configuring with serial 21firmware 20hardware 20shuttin

Seite 47 - Solaris 10 OS Training

vi Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006Product UpdatesFor product updates that you can download for the Sun Fire X4100

Seite 48

Preface viiTypographic ConventionsSun Welcomes Your CommentsSun is interested in improving its documentation and welcomes your comments andsuggestions

Seite 49

viii Sun Fire X4100 and Sun Fire X4200 Installation Guide • October 2006

Seite 50

1CHAPTER1Setting Up the Server HardwareThis chapter contains the following topics: “Installation Overview” on page 1 “Installing the Server Into a R