Sun-microsystems 6900 Bedienungsanleitung Seite 145

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 204
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 144
Chapter 9 Troubleshooting Virtualization Engine Devices 125
Sun Proprietary/Confidential: Internal Use Only
To Reset the SAN Database on a Single Virtualization
Engine
1. To disconnect the virtualization engine’s device-side FC cables, type:
2. Open a Telnet session to the virtualization engine specified in Step 1.
3. Enter the password.
The User Service Utility Menu is displayed.
4. Type 9 to clear the SAN database.
A successful command displays the message
SAN database has been cleared!
An unsuccessful command results in the service code 051.
If this occurs, repeat Steps 1 through 3.
If the command continues to fail, replace the virtualization engine.
5. To reconnect the virtualization engine’s device-side FC cables, type:
6. Type B to reboot the virtualization engine.
# setveport -v virtualization-engine-name -d
# setveport -v virtualization-engine-name -c
Seitenansicht 144
1 2 ... 140 141 142 143 144 145 146 147 148 149 150 ... 203 204

Kommentare zu diesen Handbüchern

Keine Kommentare