114 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
Note If the t3ofdg(1M) is running while you perform these steps, the following
error message is displayed:
Daemon error: check the SLIC router.
CODE EXAMPLE 9-1 FC Link Error Status Example
Note v1 represents the first virtualization engine pair
# /opt/svengine/sduc/svstat -d v1
I00001 Host Side FC Vital Statistics:
Link Failure Count 0
Loss of Sync Count 0
Loss of Signal Count 0
Protocol Error Count 0
Invalid Word Count 8
Invalid CRC Count 0
I00001 Device Side FC Vital Statistics:
Link Failure Count 0
Loss of Sync Count 0
Loss of Signal Count 0
Protocol Error Count 0
Invalid Word Count 139
Invalid CRC Count 0
I00002 Host Side FC Vital Statistics:
Link Failure Count 0
Loss of Sync Count 0
Loss of Signal Count 0
Protocol Error Count 0
Invalid Word Count 11
Invalid CRC Count 0
I00002 Device Side FC Vital Statistics:
Link Failure Count 0
Loss of Sync Count 0
Loss of Signal Count 0
Protocol Error Count 0
Invalid Word Count 135
Invalid CRC Count 0
diag.xxxxx.xxx.com: root#