50 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide — March 2002
11. Fix the FAIL condition, and then verify the settings again.
If you interrupt any of the SUNWsecfg scripts (by typing a Control-C default font,
for example), a lock file might remain in the /opt/SUNWsecfg/etc directory,
causing subsequent commands to fail. Use the following procedure to clear the lock
file.
To Clear the Lock File
1. Type the following command:
Note After any virtualization engine configuration change, the script saves a new
copy of the virtualization engine map. This may take a minimum of two minutes,
during which time no additional virtualization engine changes are accepted.
2. Monitor the /var/adm/log/SEcfglog file to see when the savevemap process
successfully exits.
# /opt/SUNWsecfg/bin/checkt3config -n t3b0
Checking : t3b0 Configuration.......
Checking command ver : PASS
Checking command vol stat : PASS
Checking command port list : PASS
Checking command port listmap : PASS
Checking command sys list : PASS
# /opt/SUNWsecfg/bin/removelocks
usage : removelocks [-t|-s|-v]
where:
-t - remove all T3+ related lock files.
-s - remove all switch related lock files.
-v - remove all virtualization engine related lock files.
# /opt/SUNWsecfg/bin/removelocks -v