Chapter 8 Troubleshooting the Sun StorEdge T3+ Array Devices 119
For Internal Use Only
t3 controller State
Change-
Red Y [ Info/Action ]
controller.u1ctr
in T3 diag213
(ip=xxx.20.67.213)
is now Not-Available
(status-state changed
from unknown to
ready-disabled)
Information: The Sun
StorEdge T3+ array
controller has been
disabled.
Recommended action:
1. Telnet to affected
Sun StorEdge T3+
array.
2. Verify the
controller state
with ‘fru stat’ and
‘sys stat’.
3. Run ‘logger -
dmprstlog’ to
capture controller
information.
4. Re-enable the
controller if
possible (enable u)
5. Replace the
controller, if
necessary.
t3 disk StateChange- Red Y [
Info/Action ]
disk.u1d5 in T3
rasd3-t3b1
(ip=xxx.0.0.41)is
now Not-Available
(status-state changed
from unknown to
fault-disabled).
Information: The Sun
StorEdge T3+ array
has reported that a
disk has failed.
Recommended action:
1. Telnet to the
affected Sun
StorEdge T3+ array
2. Verify that the disk
state is in fru
stat, fru list,
and vol stat.
3. Replace the disk, if
necessary.
Category Component EventType Sev Action Description Information