Sun Microsystems FIRE V20Z Bedienungsanleitung Seite 168

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 254
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 167
146 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide May, 2004
TABLE F-16 lists the arguments for this subcommand.
Return Codes
TABLE F-17 lists the return codes for this subcommand.
TABLE F-16 Arguments for Subcommand platform set os state boot
Arguments Description
{-f | --forced} Results in a hard power off. This option is ignored.
[-b | --bios] Allows you to reflash the BIOS image.
[-q | --quiet] Suppresses interative warning messages. No error messages are
blocked.
[-W | --nowait] If specified, the command returns immediately instead of waiting
for the operation to complete.
TABLE F-17 Return Codes for Subcommand platform set os state boot
Return Code ID Description
NWSE_Success 0 Command successfully completed.
NWSE_InvalidUsage 1 Invalid usage: bad parameter usage, conflicting
options specified.
NWSE_RPCTimeout 2 Request was issued, but was not serviced by the
server. RPC procedure timed out and the request
may or may not have been serviced by the server.
NWSE_RPCNotConnected 3 Unable to connect to the RPC server.
NWSE_NoPermission 6 Not authorized to perform this operation.
NWSE_Busy 9 Device or resource is busy.
NWSE_InvalidOpForState 22 Invalid operation for current state.
Seitenansicht 167
1 2 ... 163 164 165 166 167 168 169 170 171 172 173 ... 253 254

Kommentare zu diesen Handbüchern

Keine Kommentare